• MARINE CABLE 0012
    HVG MARINE CABLE 0012

    HVG MARINE CABLE 0012: TIOI/TICI Low voltage Shipboard power and control cable

    Application

    • Halogen free power, control and lighting cable for ships and offshore-platforms
    • Due to its flexibility also suitable when the installation space is limited and/or for places which are difficult to access
    • Suitable for areas where protection against electromagnetic interference (EMI) signals is important
    • This cable is designed for power, lighting & control circuits up to 0.6/1kV.
    • Suitable for use in commercial marine applications

    TIOI/TICI low voltage power and control cable standards

    – Design guide : IEC 60092-350 & IEC 60092-353
    – Insulation material : IEC 60092-351, XLPE
    – Sheath material : IEC 60092-359, SHF1
    – Flame retardant : IEC 60332-1 & IEC 60332-3 Category A
    – Halogen content : IEC 60754-1, 0.5%
    – Smoke emission : IEC 61034, 60%
    – Cold bend/impact : CSA 22.2 No. 0.3 (-40°C / -35°C )

    Technical specification:

    • TIOI/TICI low voltage power and control cable construction
    • TIOI/TICI low voltage power and control cable service conditions
    Classification Code Construction detail
    Conductor Stranded plain annealed copper wire as per IEC 60228, Class 2
    Insulation T XLPE as per IEC 60092-351
    Cabling – Insulated conductors shall be cabled
    – Flame retardant & non-hygroscopic fillers may be used- Suitable tape(s) may be applied on the cabled core

    – A Filler may be applied to obtain a circular Cable

    Inner sheath I SHF1 as per IEC 60092-359
    Armor O(C) – Braid of plain annealed copper wire(o) or galvanized steel wire(c)

    – Coverage density : Min. 90%

    Outer sheath I SHF1 as per IEC 60092-359,Outer sheath color : Black

    Note:
    The other color of sheath and insulation may be applicable when purchaser required.
    Stranded tinned annealed copper wire as per IEC 60228, Class 2 may be applicable when purchaser required.

    Minimum installation temperature -20 °C
    Maximum conductor temperature +90 °C
    Operating temperature min. -40 °C, max. +80 °C
    Outer sheath colour black
    Standard IEC 60092-353
    Approval Approval by most important classification societies
    American Bureau of Shipping, Bureau Veritas, Det Norske
    Veritas, Lloyds Register and Germanischer Lloyd
    Packaging drums