• AUXILIARY MACHINERT 0054
    HVG MARINE AUXILIARY MACHINERT 0054

    HVG MARINE AUXILIARY MACHINERT 0054: Vertical Hydrophore Tank

    Main technical requirements:

    • Volume: 0.12m3
    • Working pressure: 0.6MPa
    • Design pressure: 0.7MPa
    • Strength test pressure: 1.05MPa
    • Air tightness test pressure: 0.875MPa
    • Open pressure of safety valve: 0.63MPa
    • Working temperature: 0~45℃
    • Design temperature: 50℃

    Drawing:

    Technical specification:

    • Interface:
    Model Water inlet Water discharging outlet inflation inlet Discharging outlet Safety valve
    YLG-0.12 DN25 DN25 DN10 G3/4″ ZG1/2″