HVG MARINE AUXILIARY MACHINERT 0051

HVG MARINE AUXILIARY MACHINERT 0051: Hydrophore Tank 

1.Technical Requirements:

1). Flange Standard:CB/T46-1999 PN1.0;
2). The shell cover thickness including the forming thinning;
3). The system including security settings;
4). Pipes and support same as the drawings.

2. Outer Joint:

Mark Name Size Standard
a relief outlet DN32
b Water Inlet DN50 CB/T46-1999 PN1.0
c Compressor Air Inlet DN10 CB*53-80
d Water Outlet DN50 CB/T46-1999 PN1.0

 

Technical specification:

  • Design Datas:
Working Pressure 0.6Mpa
Design Pressure 0.7Mpa
Working Temp. 0~45℃
Design Temp. 50℃
Main Materials CCS-B/SS304/SS316
corrosion allowance 0.75mm
welded joint coefficient 0.6
Capacity 3.0m³
The relief valve pressure jump 0.63MPa
G.W. 865 Kgs (with standard export wooden case)
N.W. 775 Kgs