HVG OFFSHORE EQUIPMENT 0186: S11 RU(i) Offshore Cable
Application:
Fixed installation in most areas and on open deck, Meets the requirement for cable type S11+MUD in NEK TS 606:2009.
Construction:
| DESIGN | IEC 60092-376 |
| 1. Conductor | stranded tinned annalead conductor IEC 60228, class 2 |
| 2. Insulation | halogen free EP-Rubber IEC 60092-351 (HF EPR) |
| 3. Twisted pair & pair screen | two insulated cores twisted together to form a pair,plastic coated copper tape and tinned copper drain wire |
| 4. Bedding | covered by separator tape (optional) |
| 5. Sheath | halogen free thermosetting, IEC 60092-359 (SHF MUD), standard colour grey |
Technical Data
| Main characteristics | |
| 1. Rated voltage | AC 150/250V (300V) |
| 2. Max conductor temperature | + 90 °C |
| 3. Flame-retardant | IEC 60332-1-2 IEC 60332-3-22 |
| 4. Halogen-free | IEC 60754 |
| 5. Smoke emission | IEC 61034 |
| 6. Oil resistance | IEC 60811-2-1 |
| 7. MUD resistant | NEK TS 606:2009 |


