• VENTILATION EQUIPMENT 0039
    HVG MARINE VENTILATION EQUIPMENT 0039

    HVG MARINE VENTILATION EQUIPMENT 0039: Marine Rectangular Fire Damper with Grid

    Introduction :

    Marine fire damper are designed, produced and tested in accordance with CB/T3557-1995 standard. It is fulfills the requirement of SOLAS(1974) and amendments, it has passed the IMO-Resolution A.745(18) in accordance with “A”, “B”and “E” class fire test procedures code. Attachment All fire damper fire resistance test (A0, A15, A30, A60) at CSSC marine auxiliary machinery capability and environmental test center, it has get the approval of classification societies such as CCS (China), ABS (USA), GL(Germany), LR (Britain), BV (France), DNV (Norway), EC and type approve certificate.

    Sample drawing of the rectangular fire damper with grid

     

     

    Technical specification:

    • Parameters For reference

    A

    B

    L

    Cut out dimension mm

    S,D

    Z

    300

    240

    220

    340

    460×250

    400

    240

    220

    340

    560×250

    400

    300

    220

    340

    560×310

    400

    400

    250

    340

    560×410

    500

    300

    220

    340

    660×310

    500

    350

    220

    340

    660×360

    500

    400

    250

    340

    660×410

    600

    300

    220

    340

    760×310

    600

    400

    250

    340

    760×410

    600

    500

    290

    220

    760×510

    700

    500

    290

    220

    860×510

    800

    500

    290

    220

    960×510

    900

    500

    290

    220

    1060×510

    Noted: 1.We can produce and provide rectangle fire damper with grid dimension less than 1500×1500 if required by consumer

    2. The length of flameproof enclosure fire damper should be clarified before order.