• ELECTRIC EQUIPMENT 0021
    HVG MARINE ELECTRIC EQUIPMENT 0021

    HVG MARINE ELECTRIC EQUIPMENT 0021: Marine DC UPS Power Supply

    Application

    Power supply adopts the control mode of pulse width modulation, power supply has the advantages of small size, high efficiency, stable output waveform, etc.

    Marine DC UPS Power Supply has the characteristics of general UPS power, while considering the characteristics of the ship and the environmental requirements, the power supply products according to ABS and CCS specifications for design, meet the standards of marine electric.

    Features

    1)Complete range of input voltage

    a) single line single phase AC AC220V
    b) two line single phase AC AC220V
    c) three phase 380VAC
    d) direct current DC24V

    2)advanced battery management: three step charging,float charging,equalizing charge can be automatic converted, improved the battery protection.

    3)perfect protection measures: output short circuit, overload protection, the whole machine overheat protection; the input DC protection and the protection of DC over voltage protection.

    4)When the AC power out,the power supply can be switched to the input DC power supply (or battery power supply) uninterruptedly,so as to ensure uninterrupted output,out put no flush.

    Condition

    Working temperature -10℃~50℃
    Storage Temperature -40~85℃
    Relative humidity ≤90%(40±2%)
    Atmospheric pressure 70~106Kpa
    Transverse inclination ±15°
    Trim ±5°
    Rolling ±45°(Cycle 5~12S)
    Pitching ±10°(Cycle 5~7S)
    Cooling method Air cooling

    Technical specification:

    • Technical Data
    Model HVG MARINE ELECTRIC EQUIPMENT 0021
    Input Voltage AC220V±20%,Or 3 phase AC380V±20% or DC 20~32V
    Output Voltage DC26.5V±0.5V
    Output Waveform Pure sine wave, THD = 3% (resistive load)
    Output Current 6~1250A
    Efficiency ≥87%
    Insulation strength Input AC to Output,AC 1500V Input AC to the housing AC 1500V,
    Protect Function Input DC Reverse Connected Protection,Output Short-Circuit and Overload Protection,Over-heating(Internal heat sink temperature more than 85℃)