• MARINE CABLE 0050
    HVG MARINE CABLE 0050

    HVG MARINE CABLE 0050: Medium Voltage Shipboard Power Cable

    Application:

    This Cable can be applied in Marine&Offshore and various ships, ship repair and oil platforms and other offshore buildings control device and general electric lighting,machinery and equipment of factories and mines are also equally applicable.Fixed installation for medium voltage (MV) power system in both EX-and safe areas, general purposes.

    Standard applied

    IEC 60092-354 – Design
    IEC 60228 Class2 – Conductor
    IEC 60092-351 –Insulation
    IEC 60092-359 –Sheath
    IEC 60332-3-22 –Flame Retardant
    IEC 60754 –Halogen Free
    IEC 61034 –Low Smoke

    Model:

    • CJPJ85/SC
    • CJPJ95/SC
    • CJPF86/SC
    • CJPF96/SC
    • CEPJ85/SC
    • CEPJ95/SC
    • CEPF86/SC
    • CEPF96/SC

    Service Condition:

    1.Rated Voltage:3.6/6(7.2)kV,6/10(12)kV,8.7/15(17.5)kV,12/20(24)kV,18/30(36)kV,26/35kV

    2.Long term allowable working temperature:90℃

    3.Finished Cable can withstand AC 3.5kv/5 minutes without puncture.

    4.Cable bending radius

    Cable Structure Cable Outer Diameter Minimum Bending Radius
    Metal Braided Armored 6D
    Non Armored D≤25 4D
    D>25 6D

    Classification Society Certifications: CCS,ABS,LR,GL,BV,DNV,NK,KR,RINA,RS

    Technical specification:

    • Code Design:
    Components Code Material/Description
    Series Code C Shipboard/Marine Cable
    Conductor Stranded annealed copper (STC), IEC 60228 Class 2
    Conductor Screen Extruded semi-conductive layer
    Insulation E EPR,IEC 60092-351 EPR
    J XLPE,IEC 60092-351 XLPE
    Insulation Screen Extruded semi-conductive layer with copper tape wrapped outside
    Inner sheath PF Halogen-free flame retardant thermoplastic compound (SHF1)
    PJ Halogen-free flame retardant thermosetting compound (SHF2)
    Armor 8 Tinned copper wire braid (TCWB)
    9 Galvanized Steel wire braid(GSWB)
    Outer sheath 5 Halogen-free flame retardant thermoset compound (SHF2)
    6 Halogen-free flame retardant thermoplastic compound (SHF1)
    Flammability SC Low smoke,halogen free,flame retardant IEC 60332-3-22 (Cat. A)