• VENTILATION EQUIPMENT 0046 VENTILATION EQUIPMENT 0046
    HVG MARINE VENTILATION EQUIPMENT 0046

    HVG MARINE VENTILATION EQUIPMENT 0046: Grille Fire Damper

    Applications :

    • The grille damper is widely used in marine air conditioning system to prevent fire,The grill louver construction could be effective used to control the fire.
    • The damper is installed in the duct of ventilation system,At ordinary time,It is normal open,But in fire situation,closed to prevent the fire and somke.

    Features:

    • 1.Electircal close the damper.
    • 2.The damper will be closed automatically when the temperature is 70 degree.
    • 3.The voltage is DC24V
    • 4.The control vlotage is AV24V,DC24V,AC220V.
    • 5.Pneumatic operating pressure is 0.5-0.8Mpa.

    Process drawing:

    Technical specification:

    • Available size:

    A

    B

    L

    Ceiling opening

    S、D

    E

    300

    240

    220

    340

    460X250

    400

    240

    220

    340

    560X250

    400

    300

    220

    340

    560X310

    400

    400

    250

    340

    560X410

    500

    300

    220

    340

    660X310

    500

    350

    220

    340

    660X360

    500

    400

    250

    340

    660X410

    600

    300

    220

    340

    760X310

    600

    400

    250

    340

    760X410

    600

    500

    290

    220

    760X510

    700

    500

    290

    220

    860X510

    800

    500

    290

    220

    960X510

    900

    500

    290

    220

    1060X510